scientific correspondence Magnet levitation at your fingertips The stable levitation of magnets is forbid- den by Earnshaw's theorem, which states that no stationary object made of z magnets in a fixed configuration can be stability functions (MB) r 1 -1 held in stable equilibrium by any combina- 0 0 tion of static magnetic or gravitational R Kv Kh forces1­3. Earnshaw's theorem can be viewed as a consequence of the Maxwell equations, ­R which do not allow the magnitude of a magnetic field in a free space to possess a C>0 levitating maximum, as required for stable equilib- Bi cylinder magnet rium. Diamagnets (which respond to mag- ­2R netic fields with mild repulsion) are known to flout the theorem, as their negative sus- FFiigguurree 22 Levitation at your fingertips. A strong NdFeB ceptibility results in the requirement of a magnet (1.4 tesla) levitates 2.5 metres below a pow- minimum rather than a maximum in the erful superconducting magnet. The field at the levi- field's magnitude2­4. Nevertheless, levitation tation point is about 500 Gauss. of a magnet without using superconductors is widely thought to be impossible. We find where is the density of the magnet's that the stable levitation of a magnet can be material and A 1.92. Calculation shows achieved using the feeble diamagnetism of that a magnet several millimetres in size materials that are normally perceived as with remnant magnetization of about 1 being non-magnetic, so that even human tesla (NdFeB) can be levitated with a clear- fingers can keep a magnet hovering in mid- FFiigguurree 11 A NdFeB magnet (an alloy of neodymium, ance gap, D d, of several millimetres air without touching it. iron and boron; 4 mm high and 4 mm in diameter) using a 10-cm solenoid and strongly dia- Stable levitation has been demonstrated levitating at the axis of a vertical solenoid of radius magnetic Bi or graphite, in agreement with for diamagnetic objects such as supercon- R 10 cm and length 2R in a magnetic field of 100 our experiment. ducting pellets and live creatures2,5­7. Strong gauss. The levitation is stabilized by a bismuth cylin- Equation (2) depends on the product of diamagnetism of superconductors allows der ( 1.5 10 4) with inner diameter D 8 mm. and L, which means that by increasing L the situation to be reversed, so that a magnet The photograph shows the top view of the levitating (scaling up the magnet's size) we can can be levitated above a superconductor8. magnet. The right-hand plot shows the stability func- achieve the same D as above using ordinary Paramagnetic objects can also be levitated if tions Kv and Kh calculated for a solenoid with a materials (such as plastic or wood, with placed in a stronger paramagnetic medium, height of twice its radius (solid curves). Diamagnetic 10 5). To illustrate this point, we such as ferrofluid or oxygen, which makes interaction C shifts the horizontal stability function Kh show another example of a levitating mag- them effectively diamagnetic9. to the left (dashed curve) and a small region of posi- net in Fig. 2 in which human fingers We set out to lift a magnet by applying a tive U emerges above the point where Kv 0. ( 10 5) are used as diamagnetic stabi- magnetic field and then stabilizing the lizers. Here we use an alternative geometry11 intrinsically unstable equilibrium with The presence of a diamagnetic cylinder in which L is easier to scale up because it is repulsive forces from a nearby diamagnetic results in the last term in equation (1) and, determined not only by the magnet size, but material. We found that, surprisingly, the for the geometry of Fig. 1, we find that also by its strength. The levitating magnet is forces created by almost non-magnetic C 45 0| |M2/16D5, where 0 is the per- placed below a solenoid in the region where materials (susceptibility of about 10 5) meability of free space. If there is no dia- the equilibrium is stable horizontally are sufficient to stabilize levitation over dis- magnet (C 0), the stability can never be (Kh>0) but not vertically (Kv<0) (Fig. 1). tances as large as several millimetres under reached (at no point are Kv and Kh both Vertical stability is achieved by means of Earth gravity conditions, even though they positive; Fig. 1). The diamagnetic interac- two horizontal diamagnetic plates (or by decay rapidly with distance as 1/x5 (Fig. 1). tion allows the energy U to have a mini- the fingertips). For stable levitation, an equilibrium mum (Kv>0 and Kh+C>0) which In this geometry, the positive constant requires that the magnetic force MB (z) emerges for C>MB (z)2/8B(z) just above C 6 0 M2/ D5 counters Kv and the levi- compensates the gravitational force mg, the point of a maximum field gradient tation condition is similar to equation (2), where M is the magnetic moment and B(z) (B (z) 0). It is counterintuitive that levi- except that now D denotes the separation and B (z) are the magnetic field on the axis tation is easiest in the most inhomogeneous between the plates, A 1.02 and L 4B /B and its derivative, respectively. For the equi- field region, rather than in the centre of a is approximately the distance from the cen- librium to be stable, it must be in a region solenoid where the field is almost uniform. tre of a solenoid to a levitating magnet. The where the total energy of the magnet It is instructive to introduce a character- larger the distance, the easier it is to stabilize U MB(r)+mgz+Udia has a minimum istic scale L on which the field changes: levitation by diamagnetic repulsion. L is ( U>0), where Udia is the energy of dia- B B/L. At the optimum levitation point limited by the requirement on the field gra- magnetic interaction with the cylinder. (B (z) 0), L varies between R and 1.2R dient, B (z) mg/M. To reach such a large Close to the equilibrium position at the for long and short solenoids, respectively. If L, as in Fig. 2, we used an 11-tesla supercon- field axis3,10, we approximate our levitating magnet by a ducting solenoid a metre in diameter. If U U0+[mg MB (z)]z+Kvz2+Khr2+ sphere of diameter d with a remnant field stronger diamagnets are used (such as Cr2+... (1) Br, then M ( /4 0)Brd3, and the require- graphite or bismuth), this type of levitation where Kv(z) MB (z)/2 and ment for levitation becomes can also be achieved with small permanent K 2 h(z) M[B (z)2 2B(z)B (z)]/8B(z). A( LBr d3/ 0 g)1/5>D>d (2) magnets, making miniature hand-held NATURE | VOL 400 | 22 JULY 1999 | www.nature.com © 1999 Macmillan Magazines Ltd 323 scientific correspondence devices accessible to everyone (M. D. S., unpublished data). These could replace the a b c mN mN mN existing servo levitation devices for some applications. A. K. Geim*, M. D. Simon , M. I. Boamfa*, L. O. Heflinger mN" mN" mN" *High Field Magnet Laboratory, University of Nijmegen, 6525 ED Nijmegen, The Netherlands mShore mShore mShore e-mail: geim@sci.kun.nl d e f Department of Physics and Astronomy, University of California at Los Angeles, Los Angeles, California 90095, USA 1. Earnshaw, S. Trans. Camb. Phil. Soc. 7, 97­112 (1842). 2. Brandt, E. H. Science 243, 349­355 (1989). P< 0.001 P< 0.001 3. Berry, M. V. &. Geim, A. K. Eur. J. Phys. 18, 307­313 (1997). 4. Thomson, W. (Lord Kelvin) Reprints of Papers on Electrostatics mShore mShore and Magnetism (Macmillan, London, 1872). g h 5. Braunbeck, W. Z. Phys. 112, 753­763 (1939). 6. Beaugnon, E. & Tournier, R. Nature 349, 470 (1991). 7. Geim, A. Phys. Today 51, 36­39 (September 1998). 8. Arkadiev, A. Nature 160, 330 (1947). 9. Ikezoe, Y. et al. Nature 393, 749­750 (1998). 10.Simon, M. D. et al. Am. J. Phys. 65, 286­292 (1997). P< 0.001 11.Boerdijk, A. H. Philips Tech. Rev. 18, 125­127 (1956). FFiigguurree 11 Effects of long-wavelength light and head caps on bimodal magnetic orientation in newts. a­c, Pre- dicted orientation of newts (double-headed arrow) and their perception of the direction of the magnetic field Extraocular magnetic (single-headed arrow)5,6. Training tanks have the shore towards magnetic north (mN); circular test arenas show the predicted response of the newts under either full-spectrum (beige) or long-wavelength light (yel- compass in newts low). a, Full-spectrum training and testing: newts should perceive the shore to be towards magnetic north and exhibit bimodal magnetic orientation along the shoreward axis. b, Full-spectrum training, long-wavelength testing: newts' perception of magnetic north in testing, and their orientation in the test arena, should be rotated Geomagnetic orientation is widespread 90º (mN ) from magnetic north during training. c, Long-wavelength training and testing: newts' perception of among organisms, but the mechanism(s) of the magnetic field should be rotated 90º relative to the actual field during training and testing. Their percep- magnetoreception has not been identified tion of the magnetic field in the arena would be the same as in the outdoor tank. d­h, Results. Data points convincingly in any animal1. In agreement show the magnetic bearing of a newt tested in one of four symmetrical alignments of an Earth-strength mag- with biophysical models proposing that the netic field (magnetic north is geographic north (gN), east (gE), west (gW) or south (gS)). The magnetic field geomagnetic field interacts with photo- was altered by two orthogonally orientated, double-wrapped, Ruben's coils around the test arena7. Data are receptors2­4, changes in the wavelength of plotted with respect to the magnetic direction of shore (mShore) in the training tank (shore direction, 360º). light have been shown to influence magnetic Double-headed arrows indicate mean axis of orientation with the mean axis length, r, proportional to the compass orientation in an amphibian, an strength of orientation (diameter of the circle corresponding to r 1). Dashed lines indicate 95% confidence insect and several species of birds (reviewed intervals for the mean axis. Distributions are significant at P<0.05 or less by the Rayleigh test and P-values in ref. 5). We find that light-dependent mag- between circle plots indicate significant differences between distributions (Watson U2 test). d, Newts trained netic orientation in the eastern red-spotted under natural light and tested under full-spectrum light orientated along the shoreward axis5. e, Newts trained newt, Notophthalmus viridescens, is mediated under natural light and tested under long-wavelength light orientated 90º from the shoreward direction (filled by extraocular photoreceptors, probably circles; tested under broadband long-wavelength ( 500 nm) light; filled squares, tested under a 550-nm light, located in the pineal complex or deeper in 40 nm bandwidth, 12.5 0.1 log Quanta cm 2 s 1; ref. 5). f, Newts trained and tested under long-wavelength the brain (perhaps the hypothalamus). light orientated along the shoreward axis5. g, After training under natural light, clear-capped newts tested under Experiments investigating shoreward long-wavelength light orientated ~90º from the shoreward direction. h, After training under natural light, newts magnetic compass orientation have demon- with long-wavelength-transmitting caps orientated along the shoreward axis under long-wavelength light. strated that the newt's perception of the direction of the magnetic field is rotated 90o due to a direct effect of light on the newts' tors. Small round `caps' (5 mm in diameter) under long-wavelength (greater than 500 perception of the magnetic field, we trained were attached to the dorsal surface of the nm) light5,6. We recently trained newts newts under long-wavelength light by cov- head of each newt using cyanoacrylate glue, under natural skylight to aim for the shore ering the training tank with a long-wave- and remained in place during both training by placing them for 12­16 hours in water- length-transmitting gel filter (two layers of and testing. Equal numbers of newts were filled tanks with an artificial shore at one Lee #101)5. Under long-wavelength light, capped with either a clear filter (Lee #130) end5,7. The magnetic orientation of individ- these newts orientated themselves parallel or a filter that transmitted only long-wave- ual newts was then tested in a circular, visu- to the shoreward axis, indicating that they length light (equivalent to two layers of Lee ally symmetrical indoor arena under had learned the direction of the shore with #101). The caps were positioned to alter the depolarized light. Under full-spectrum light respect to the rotated magnetic information spectral properties of light reaching the (from a xenon arc source), they exhibited under long-wavelength light (Fig. 1c,f). pineal and surrounding structures, whereas bimodal magnetic orientation parallel to As well as ocular photoreceptors, newts light reaching the eyes was unaffected. the shoreward axis in the training tank (Fig. have extraocular photoreceptors in the Clear-capped newts were tested to control 1a,d). In contrast, under long-wavelength pineal complex8 and possibly the hypothal- for any nonspecific effects of the caps on the light, they orientated themselves perpendic- amus9. To determine which photoreceptors newts' orientation behaviour. ular to the shoreward direction (Fig. 1b,e). are involved in the magnetic compass All newts were trained outdoors under To demonstrate that the 90o shift in ori- response, we manipulated the wavelength of natural skylight and tested for magnetic ori- entation under long-wavelength light was light reaching the extraocular photorecep- entation in the testing arena under long- 324 © 1999 Macmillan Magazines Ltd NATURE | VOL 400 | 22 JULY 1999 | www.nature.com